124
MENU VIDEO/TEXT ADJUST
- FLICKERFREE | ON |
- LINE INTERP. | ON |
- SHARPNESS | 2 |
- BNC OUT | VBS |
Y/C DATA |
|
ON |
-MINI MON DATA ON
-TXT WHITE LEV. 2
- TXT INVERS | OFF | |
- | TXT FINE POS | 2 |
- | EXIT |
|
GENLOCK on/off
It is possible to synchronize the IVS to an external video signal, thus allowing the user to switch between different video signals without synchronizing problems.
•Connect a standard video signal of the same type as the video system (PAL or NTSC) to the Video output with no data
•Move the cursor > with the keys Ê and Ë to the line
– GENLOCK. Pressing the key Í or Ì will switch genlock ON or OFF.
The video signal out of the connector for video with data is now synchronized to the incoming video signal connected to the other BNC socket.
Note: | GENLOCK is only available, if the output is on |
| VBS mode. |
Note: | This setting is switched back to GENLOCK off after |
| the IVS is started (after power down/power up) |
| to avoid accidental operation. |