ARRIFLEX 416 Plus

status LED

Zoom

direction switch

Focus

Iris

LCS bus connectors

12.3 Wireless Remote System

Lens Motors

Both CLM-1 and CLM-2 motors can be used with the ARRIFLEX 416 Plus.

CLM-1 motors should be daisy-chained in series with one of the end motors connected to either (but not both) of the 416 Plus LCS bus connectors Aphoto.

CLM-2 motors should be connected, according to their position on the lens, to the Zoom, Focus and Iris connectors of the 416 Plus Aphoto.

CLM-1 and CLM-2 motors may be used simultaneously but only on different lens axes.

In the situation where a CLM-1 is assigned to Focus and a CLM-2 is simultaneously plugged into the Focus connector, the CLM-1 will have priority and the CLM-2 connection will be deactivated. The same applies to the Zoom and Iris axes.

Each CLM-2 motor connection has a direction switch Aphoto and a status LED Aphoto.

Use the direction switch to change the direction of rotation of the attached motor.

188