Technical Data

Operating Temperature Range

-20°C to +50°C (-4°F to +122°F)

Power Supply

24 V DC

 

Acceptable voltage range: ........................................................

20.6…35 V DC

Viewfinder Warning Indicators

Low power supply voltage (BAT)

Asynchronous running (ASY)

 

IVS

 

Weight.....................................................................................

approx. 0.49 kg

Power Consumption.....................................................................

approx. 4.8W

Inputs.......................................................................................................

None

Outputs:.................................

2 BNC outputs for composite video or alternatively

 

Y - C (S-video) over 2 BNC connectors

 

& 2 Mini-Monitor outputs

Optic.............................................................................

covers Super 16 format

Optic Alignment:............................................................

X, Y, rotation and focus

Dimensions

Length

with magazine & viewfinder, without lens:.........................

405mm (16”)

Width

with viewfinder on the left:

 

 

(w/o handgrip).........................................................

220mm (8 5/8”)

 

(with handgrip)........................................................

282mm (11 1/8”)

 

with viewfinder on the right:............................................

254mm (10“)

Height

with grip:.........................................................................

230mm (9”)

 

without grip:..............................................................

180mm (7 1/8“)

Weight

 

 

ARRIFLEX 416 Plus camera body

 

with loaded magazine, viewfinder, eyepiece, IVS but no lens:.....

5.5 kg (12.1 lbs)

224