Resetting the Film Counter (Modes 1 and 3)

Change to the mode which shows the total exposed film counter (“MODE” button).

The total exposed film counter can be set to zero by pressing the “SET” button (for at least 1.5 seconds) while in Standby.

The take length counter is automatically reset each time the camera is started.

Setting the Total Exposed Film Counter (Mode 1)

The Total Exposed Film Counter can only be set in Mode 1 (see Setting the Film Counter Configuration above).

Use the “SEL“ button to select the total exposed film counter digit you wish to change, which will start to flash.

Use the “SET“ button to change the value of the flashing digit.

Changing the Unit of Measurement (Meters/Feet) (Mode 3)

Change from Mode 1 to Mode 3 by pressing the “MODE” button twice.

Press the “SEL” button once; the symbol m/ft blinks.

Press the “SET” button within three seconds to change the unit of measurement.

Displaying the Angle of the Mirror Shutter (Mode 1)

Press and hold the “PHASE” button while in Standby. The set angle of the mirror shutter appears in the upper display line.

The camera runs at inching speed.

Setting the shutter angle: see Chapter 7.

Camera Operation

61