Chapter 10 Managing PNNI Routing
160 Avaya M770 ATM Switch User’s Guide
Set PNNI SVCC timers
Use the following command to set the PNNI node SVCC timers:
Note: This request will set value for SVCC timers according to the index parameter.
Changes will take effect immediately.
PNNI Timers
Show PNNI node timers
Use the following command to show the PNNI node timers:
The user is not expected to change any of these timers. However, if you need more
information about these timers you may refer to the PNNI specification
(af-pnni-0055.000), Annex E: Architectural Variables.
The <level> parameter is optional – if it is omitted, timers of all levels will be
displayed.
Command: M15-155s8:/>route pnni config svcc set <level> <index>
<value>
Parameters: <level> - internal PNNI level number: 1 is the physical
node
<index> - the index of the timer, to set all timers type
'all'
<value> - the value that the selected timer will receive
Command: M15-155s8:/>route pnni config timers show <level>
Examples: Timers :
Name Index Current Default
Value Value Range Units
-----------------------------------------------------------------
PtseHoldDown 1 10 10 [ 1 - 600] 100ms
HelloHoldDown 2 10 10 [ 1 - 600] 100ms
HelloInterval 3 15 15 [ 1 - 600] secs
HelloInactivityFactor 4 5 5 [ 1 - 20] fctr
HlinkInactivityTime 5 120 120 [ 1 - 600] secs
PtseRefreshInterval 6 1800 1800 [ 60 - 3600] secs
PtseLifeTimeFactor 7 200 200 [100 - 500] %
RxmtInterval 8 5 5 [ 1 - 60] secs
RDelayedAckInterval 9 10 10 [ 1 - 600] 100ms
AvcrPm 10 50 50 [ 1 - 99] %
AvcrMt 11 3 3 [ 1 - 99] %
CdvPm 12 25 25 [ 1 - 99] %
CtdPm 13 50 50 [ 1 - 99] %