60-13
Cisco ASA 5500 Series Configuration Guide using the CLI
Chapter60 Configuring the ASA CSC Module
Monitoring the CSC SSM
What to Do Next
See the “Monitoring the CSC SSM” section on page 60-13.
Monitoring the CSC SSM
To check the status of a module, enter one of the following commands:
Examples
The following is sample output from the show module command for an ASA with a CSC SSM installed:
hostname# show module
Mod Card Type Model Serial No.
--- -------------------------------------------- ------------------ -----------
0 ASA 5520 Adaptive Security Appliance ASA5520 JMX1241L05S
1 ASA 5500 Series Content Security Services Mo ASA-SSM-CSC-10 AF1234BQQL
Mod SSM Application Name Status SSM Application Version
--- ------------------------------ ---------------- --------------------------
1 CSC SSM Down 6.2.1599.0
The following is sample output from the show module details command, which provides additional
information about an ASA with a CSC SSM installed:
hostname# show module 1 details
Getting details from the Service Module, please wait...
ASA 5500 Series Security Services Module-20
Model: ASA-SSM-20
Hardware version: 1.0
Serial Number: JAF10333331
Firmware version: 1.0(10)0
Software version: Trend Micro InterScan Security Module Version 6.2
App. name: Trend Micro InterScan Security Module
App. version: Version 6.2
Data plane Status: Up
Status: Up
HTTP Service: Up
Mail Service: Up
FTP Service: Up
Activated: Yes
Mgmt IP addr: 209.165.200.225
Mgmt web port: 8443
The following is sample output from the show module recover command, which includes recovery
details for an ASA with a CSC SSM installed:
hostname# show module 1 recover
Module 1 recover parameters. . .
Boot Recovery Image: Yes
Image URL: tftp://10.21.18.1/ids-oldimg
Port IP Address: 209.165.200.230
Command Purpose
show module Displays the status.
show module 1 details Displays additional status information.
show module 1 recover Displays the network parameters for transferring an image to the module.