2-79
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
Chapter2 Alarm Troubleshooting
2.7.119 INVMACADR

Clear the INTRUSION-PSWD Condition

Step1 In node view, click the Provisioning > Security tabs.
Step2 Click Clear Security Intrusion Alarm.
Step3 If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call CiscoTAC (1-800-553-2447).
2.7.119 INVMACADR
Default Severity: Major(MJ), Service-Affecting (SA)
SONET Logical Object: BPLANE
The Equipment Failure Invalid MAC Address alarm occurs when the ONS15310-CL or
ONS 15310-MA MAC address is invalid. The MAC Address is permanently assigned to the chassis when
it is manufactured. Do not attempt to troubleshoot an INVMACADR alarm. Log into the Technical
Support Website at http://www.cisco.com/techsupport for more information or call CiscoTAC
(1-800-553-2447).
2.7.120 IOSCFGCOPY
Default Severity: NotAlarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: EQPT
The IOS Configuration Copy in Progress condition occurs on ML-100T-8 Ethernet cards when a
Cisco IOS startup configuration file is being uploaded or downloaded to or from an ML-100T-8 Ethernet
card. (This condition is very similar to the “SFTWDOWN” condition on page2-127 but it applies to
ML-100T-8 Ethernet cards rather than to the controller card.)
The condition clears after the copy operation is complete. (If it does not complete correctly, the
“NO-CONFIG” condition on page2-111 could be raised.)
Note IOSCFGCOPY is an informational condition.
Note For more information about the Ethernet cards, refer to the CiscoONS 15310-CL and
Cisco ONS 15310-MA Ethernet Card Software Feature and Configuration Guide.
2.7.121 ISIS-ADJ-FAIL
Default Severity: Minor(MN), Non-Service-Affecting (NSA)
SONET Logical Object: OCN