2-114
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
Chapter2 Alarm Troubleshooting
2.7.182 PDI-P
A PDI-P condition reported on an OC-3 or OC-12 port supporting an ONS15310-CL or ONS 15310-MA
Ethernet card circuit could result from the end-to-end Ethernet link integrity feature of the Ethernet card.
If the link integrity is the cause of the path defect, it is typically accompanied by the “CARLOSS
(EQPT)” alarm on page 2-35 reported against one or both Ethernet ports terminating the circuit. If this
is the case, clear the TPTFAIL and CARLOSS alarms to resolve the PDI-P condition.
Warning
Invisible laser radiation could be emitted from the end of the unterminated fiber cable or connector.
Do not stare into the beam directly with optical instruments. Viewing the laser output with certain
optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of
100mm could pose an eye hazard.
Statement 1056
Warning
Use of controls, adjustments, or performing procedures other than those specified could result in
hazardous radiation exposure.
Statement 1057
Clear the PDI-P Condition
Step1 Verify that all circuits terminating in the reporting card are in an active state by completing the following
steps:
a. Click the Circuits tab.
b. Verify that the Status column lists the port as active.
c. If the Status column lists the port as incomplete, wait 10 minutes for the ONS15310-CL or
ONS 15310-MA to initialize fully. If the incomplete state does not change after full initialization,
log into the Technical Support Website at http://www.cisco.com/techsupport for more information
or call Cisco TAC to report a Service-Affecting(SA) problem (1-800-553-2447).
Step2 After determining that the port is active, ensure that the signal source to the card reporting the alarm is
working.
Step3 If traffic is affected, complete the “Delete a Circuit” procedure on page2-155.
Caution Deleting a circuit can affect existing traffic.
Step4 Recreate the circuit with the correct circuit size. Refer to the “Create Circuits” chapter in the
Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide for procedures.
Step5 If the circuit deletion and re-creation does not clear the condition, verify that there is no problem with
the far-end OC-3 or OC-12 port providing STS payload to the reporting card.
Step6 If the condition does not clear, confirm that the cross-connect between the OC-3 or OC-12 port and the
reporting port is good.
Step7 If the condition does not clear, clean the far-end optical fiber according to site practice. If no site practice
exists, complete the procedure in the “Maintain the Node” chapter in the CiscoONS 15310-CL and
Cisco ONS 15310-MA Procedure Guide.
Caution Always use the supplied electrostatic discharge wristband when working with a powered ONS15310-CL
or ONS 15310-MA.