2-111
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
Chapter2 Alarm Troubleshooting
2.7.175 MEM-GONE
2.7.175 MEM-GONE
Default Severity: Major(MJ), Non-Service-Affecting (NSA)
SONET Logical Object: EQPT
The Memory Gone alarm occurs when data generated by software operations exceeds the memory
capacity of the 15310-CL-CTX or CTX2500 card. CTC does not function properly until the alarm clears.
The alarm clears when additional memory becomes available.
The alarm does not require user intervention. If the alarm does not clear, log into the Technical Support
Website at http://www.cisco.com/techsupport for more information or call CiscoTAC
(1-800-553-2447).
2.7.176 MEM-LOW
Default Severity: Minor(MN), Non-Service-Affecting (NSA)
SONET Logical Object: EQPT
The Free Memory of Card Almost Gone alarm occurs when data generated by software operations is
close to exceeding the memory capacity of the 15310-CL-CTX or CTX2500 card. The alarm clears when
additional memory becomes available. If additional memory is not made available and the memory
capacity of the card is exceeded, CTC ceases to function.
Note The alarm does not require user intervention. If the alarm does not clear, log into the Technical Support
Website at http://www.cisco.com/techsupport for more information or call CiscoTAC
(1-800-553-2447).
2.7.177 MFGMEM
Default Severity: Critical(CR), Service-Affecting (SA)
SONET Logical Objects: BPLANE, FAN, PPM
The Manufacturing Data Memory Failure alarm occurs when the electronically erasable programmable
read-only memory (EEPROM) fails on a card or component, or when the 15310-CL-CTX or CTX2500
card cannot read this memory. EEPROM stores manufacturing data that a 15310-CL-CTX card uses to
determine system compatibility and shelf inventory status. Unavailability of this information can cause
less-significant problems.
To clear the MFGMEM alarm, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call CiscoTAC (1-800-553-2447) to report
a Service-Affecting (SA) problem.
2.7.178 NO-CONFIG
Default Severity: NotAlarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: EQPT