1-5
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
Chapter1 General Troubleshooting
1.2.1 Perform a Facility Loopback on a Source-Node Port
Step3 Use CTC to create the facility loopback on the port being tested:
a. In node view, double-click the card where you are performing the loopback, then click the
appropriate tab:
Maintenance > DS1 > Loopback
Maintenance > DS3 > Loopback
Maintenance > EC1 > Loopback
b. Choose OOS,MT from the Admin State column for the port being tested.
c. Choose Facility from the Loopback Type column for the port being tested.
d. Click Apply.
e. Click Yes in the confirmation dialog box.
Note It is normal for a facility loopback 2.7.156 LPBKFACILITY (DS1, DS3) or
2.7.157 LPBKFACILITY (EC1) condition to appear during loopback setup. The condition
clears when you remove the loopback.
Step4 Continue with the “Test the Facility Loopback” procedure on page1-5.
Test the Facility Loopback
Step1 If the test set is not already sending traffic, send test-set traffic on the loopback circuit.
Step2 Examine the traffic received by the test set. Look for errors or any other signal information that the test
set is capable of indicating.
Step3 If the test set indicates a good circuit, complete the following steps:
a. Double-click the electrical card, then click the appropriate tab:
Maintenance > DS1 > Loopback
Maintenance > DS3 > Loopback
Maintenance > EC1 > Loopback
b. Choose None from the Loopback Type column for the port being tested.
c. Choose the appropriate state (IS,AINS; OOS,DSBLD; or OOS,MT) from the Admin State column
for the port being tested.
d. Click Apply.
e. Click Yes in the confirmation dialog box.
Step4 If the test set indicates a faulty circuit, the problem might be a faulty card, faulty port, or faulty cabling
from the electrical port. Continue with the “Test the Electrical Cabling” procedure on page1-6.