Chapter 4 Error Messages

Table 4-1

Error Messages (continued)

 

 

 

 

Error Warning

 

 

ID

Error Warning Message

Description

 

 

 

EID-3050

An exception was caught trying to save the file to your local file

Check whether the file already exists and

 

system.

cannot be over written, or there isa space

 

 

constraint in the file system.

 

 

 

EID-3051

The maximum size for a config file in bytes is: {0}

The size of the configuration file should not

 

 

exceed the specified number of bytes.

 

 

 

EID-3052

There was an error saving the config file to the TCC.

Refer to the error message text.

 

 

 

EID-3053

The value of {0} must be between {1} and {2}

The value of the item must be between the

 

 

specified values.

 

 

 

EID-3054

Cannot remove provisioned input/output ports or another user

Another user may be updating the card. You

 

is updating the card, please try later.

can try again later.

 

 

 

EID-3055

Cannot create soak maintance pane.

Refer to the error message text.

 

 

 

EID-3056

Cannot save defaults to file {0}

CTC cannot save the defaults to the

 

 

specified file.

 

 

 

EID-3057

Cannot load default properties from the node.

Refer to the error message text.

 

 

 

EID-3058

File {0} does not exist.

Refer to the error message text.

 

 

 

EID-3059

Error encountered while refreshing.

There was an error while refreshing.

 

 

 

EID-3060

The ALS Recovery Pulse Interval must be between {0} seconds

The automatic laser shutdown (ALS)

 

and {1} seconds.

Recovery Interval must be between the

 

 

specified range of seconds.

 

 

 

EID-3061

The ALS Recovery Pulse Duration must be between {0}

The automatic laser shutdown (ALS)

 

seconds and {1} seconds.

Recovery Duration must be between the

 

 

specified range of seconds.

 

 

 

EID-3062

Error encountered while setting values.

Refer to the error message text.

 

 

 

EID-3064

Not a G1000 Card.

This card is not a G1000-4 card.

 

 

 

EID-3065

An error was encountered while attempting to create RMON

You must wait some time before you try

 

threshold:

again.

 

{0}

 

 

 

 

EID-3066

Minimum sample period must be greater than or equal to 10.

Refer to the error message text.

 

 

 

EID-3067

Rising Threshold: Invalid Entry, valid range is from 1 to {0}

This is an invalid rising threshold entry. The

 

 

valid range is from 1 to the specified value.

 

 

 

EID-3068

Falling Threshold: Invalid Entry, valid range is from 1 to {0}

This is an invalid falling threshold entry.

 

 

The valid range is from 1 to the specified

 

 

value.

 

 

 

EID-3069

Rising threshold must be greater than or equal to falling

Refer to the error message text.

 

threshold.

 

 

 

 

EID-3070

Error in data for ports {0} Exactly one VLAN must be marked

CTC encountered data error for the

 

untagged for each port. These changes will not be applied.

specified ports. Only one VLAN should be

 

 

marked untagged for each port.

 

 

 

EID-3071

Get Learned Address

Unable to retrieve the learned MAC address

 

 

from the NE.

 

 

 

Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0

4-17

Page 295
Image 295
Cisco Systems ONS 15310-MA, ONS 15310-CL manual Error Warning Message Description

ONS 15310-CL, ONS 15310-MA specifications

Cisco Systems has long been a leader in networking and telecommunications technology, and among its impressive lineup of products, the Cisco ONS 15310 series stands out as an essential solution for optical networking. This series includes models such as the ONS 15310-MA, ONS 15310-CL, and ONS 15310-CA, each designed to meet the diverse needs of service providers and enterprises seeking to enhance their optical transport networks.

The Cisco ONS 15310-MA is an advanced multi-service platform designed for metropolitan area networks. It facilitates the seamless transport of data, voice, and video over optical networks. One of its main features is its ability to support a variety of interfaces, including Ethernet, SONET/SDH, and Wavelength Division Multiplexing (WDM), allowing users to integrate multiple services into a single platform. Additionally, the ONS 15310-MA supports advanced traffic management and Quality of Service (QoS) features to prioritize critical applications and ensure consistent performance.

The ONS 15310-CL variant is tailored for more specific applications, providing enhanced capabilities aimed at delivering carrier-grade services. It features a robust architecture that accommodates high-capacity traffic without compromising reliability. This model emphasizes low power consumption and a compact design, making it suitable for deployment in space-constrained environments. The ONS 15310-CL also supports a wide range of optical interfaces, making it highly flexible for various network configurations.

In terms of technologies, the Cisco ONS 15310 series leverages Optical Transport Network (OTN) capabilities, providing high efficiency and greater bandwidth utilization. OTN technology enables efficient error correction and adds resilience to the network through its built-in protection mechanisms. Furthermore, the series supports seamless integration with existing IP/MPLS networks, creating a cohesive infrastructure as organizations evolve their networking requirements.

One of the defining characteristics of the ONS 15310 series is its focus on scalability. Network operators can start with a modest deployment and gradually expand capacity as demand grows. This adaptability is complemented by Cisco's comprehensive management and monitoring tools, providing operators with real-time insights into network performance and facilitating proactive management.

In conclusion, the Cisco ONS 15310-MA and ONS 15310-CL models represent sophisticated solutions for modern optical networks. With their versatile features, advanced technologies, and robust design, they empower service providers and enterprises to build resilient, high-capacity networks that meet the demands of today’s data-driven world.