2-43
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
Chapter2 Alarm Troubleshooting
2.7.46 DATAFLT
Note When you replace a card with the identical type of card, you do not need to make any changes
to the database.
Step4 If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call CiscoTAC (1-800-553-2447) in order to report a Service-Affecting (SA)
problem.
2.7.46 DATAFLT
Default Severity: Minor(MN), Non-Service-Affecting (NSA)
SONET Logical Object: NE
The Software Data Integrity Fault alarm occurs when the 15310-CL-CTX card or CTX2500 card exceeds
its flash memory capacity.

Clear the DATAFLT Alarm

Step1 Complete the “Soft- or Hard-Reset a Controller Card” procedure on page2-153.
Caution Avoid soft-resetting multiple ONS15310-MA cards at one time; doing so might cause an unexpected
traffic hit.
Step2 If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call CiscoTAC (1-800-553-2447).
2.7.47 DBOSYNC
Default Severity: Major(MJ), Service-Affecting (SA)
Logical Object: NE
The Standby Database Out Of Synchronization alarm applies to the ONS15310-MA platform and occurs
when the standby CTX2500 card database does not synchronize with the active database on the active
CTX2500 card.
Caution If you reset the active CTX2500 card while this alarm is raised, you will lose current provisioning.

Clear the DBOSYNC Alarm

Step1 Save a backup copy of the active CTX2500 card database. Refer to the “Maintain the Node” chapter in
the Cisco ONS 15310-CL and CiscoONS 15310-MA Procedure Guide for procedures.