Chapter 2 Preparing for Installation

PRP Port Connection Guidelines

Table 2-5lists the cabling specifications for 100-Mbps transmission over unshielded twisted-pair (UTP) cables.

Note The transmission speed of the Ethernet ports is autosensing by default and is user-configurable.

Table 2-5

Specifications and Connection Limits for 100-Mbps

 

Transmission

 

 

 

Parameter

 

RJ-45

 

 

Cable specification

Category 51 UTP, 22 to 24 AWG2

Cable length (max)

 

 

Segment length (max)

328 feet (100 m) for 100BASE-TX

 

 

Network length (max)

656 feet (200 m)3 with 1 repeater

1.EIA/TIA-568 or EIA-TIA-568 TSB-36 compliant. Not supplied by Cisco.

2.AWG = American Wire Gauge. This gauge is specified by the EIA/TIA-568 standard.

3.Specifically the length between any two stations on a repeated segment.

Table 2-6lists IEEE 802.3u physical characteristics for 100BASE-TX.

Table 2-6

IEEE 802.3u Physical Characteristics

 

 

 

Parameter

 

100BASE-TX

 

 

Data rate (Mbps)

100

 

 

Signaling method

Baseband

 

 

Maximum segment length

100 m between DTE and repeaters

 

 

 

Media

 

Category 5 UTP

 

 

 

Topology

 

Star/Hub

 

 

 

 

Cisco XR 12410 Router Installation Guide

2-30

OL-13832-01

Page 74
Image 74
Cisco Systems XR 12410 manual 100BASE-TX