Chapter 4 Troubleshooting the Installation
Troubleshooting the Power Subsystem
Troubleshooting the Power Distribution System
The power distribution system consists of:
•AC or DC PEMs which supply
•The chassis backplane which carries voltage to chassis components.
•
Use the following procedure to troubleshoot the power distribution system.
Step 1 Check each power supply to make sure that:
•The ejector lever is fully closed and properly secured by the its captive screw.
•The Pwr OK indicator is on.
•The Fault and Temp indicators are both off.
If the power supplies meet the above criteria, then the correct source power is present and within tolerance. The power supplies are functioning properly.
Step 2 Make sure the blower module is operating.
•If the blower module is functioning, then the
•If the blower module is not functioning, there may be a problem with either the blower module itself, or the
•If the blower module is still not operating there could be a problem with the blower module controller card or cable. Replace the blower module.
•Contact your Cisco representative if replacing the blower module does not fix the problem.