Appendix A Technical Specifications

Router Specifications

Table A-2

AC Electrical Specifications

 

 

 

Description

 

Value

 

 

Total AC Input Power

3000 VA (volt-amps) per AC power supply

 

 

(2 AC power supplies per system)

 

 

Rated input voltage1

200–240 VAC nominal (range: 180 to 264 VAC)

 

 

220–240 VAC (UK)

 

 

Rated input line frequency1

50/60 Hz nominal (range: 47 to 63 Hz)

 

 

50/60 Hz UK

 

 

 

Input current rating1

15

A maximum @ 200 VAC

 

 

13

A maximum @220 to 240 VRMS (UK)

 

 

 

Source AC service

20

A North America; 16 A international;

requirement1

 

13

A UK

Heat dissipation

2800 W@9,544 BTU/hour

(total maximum)

 

 

 

 

 

Redundancy

 

2 AC power supply modules required for 2N

 

 

redundancy

 

 

 

 

1. For each AC power supply module.

Caution To ensure that the chassis configuration complies with the required power budgets, use the on-line power calculator. Failure to properly verify the configuration may result in an unpredictable state if one of the power units fails. Contact your local sales representative for assistance.

 

 

Table A-3

DC Electrical Specifications

 

 

 

 

 

 

 

Description

 

Value

 

 

 

 

 

 

Total DC Input Power

2800 W per DC power entry module

 

 

 

 

 

 

Rated input voltage1

–48 VDC nominal in North America

 

 

 

 

–60 VDC nominal in the European Community

 

 

 

 

(range: –40.5 to –72 VDC (–75 VDC FOR 5mS))

 

 

 

 

 

 

Input current rating1

40 A maximum (2x)

 

 

 

 

Cisco XR 12410 Router Installation Guide

 

 

 

 

 

 

 

 

OL-13832-01

 

 

 

A-3

 

 

 

 

Page 213
Image 213
Cisco Systems XR 12410 manual Table A-2 AC Electrical Specifications