Chapter 4 Troubleshooting the Installation

Troubleshooting Overview

Identifying Startup Issues

Table 4-1shows the contents of the alphanumeric displays on the RP and the line cards, as well as the normal LED states on the alarm card, the power entry modules (AC or DC), and the blower module after a successful system startup.

Table 4-1

Alphanumeric Displays and LEDs at System Startup

 

 

 

Component

Type of Indicator

Display Contents/LED Status and Meaning

 

 

 

RP

Alphanumeric

Top row: MSTR

 

display

Bottom row: PRP

 

 

The RP is enabled and recognized by the system; a valid

 

 

Cisco software image is running.

 

 

 

Line Cards

Alphanumeric

Top row: IOS XR

 

display

Bottom row: RUN

 

 

The line card is enabled and ready for use.

 

 

 

Alarm Display

Detected alarm

Critical: Off

 

severity

Major: Off

 

 

Minor: Off

 

MBUS (Alarm A and

Enabled: On

 

Alarm B cards)

Fail: Off

 

CSC 0 and 1

Enabled: On

 

 

Fail: Off

 

SFC 0, 1, 2, 3, and 4

Enabled: On

 

 

Fail: Off

 

 

 

AC Power

Power status

Pwr OK: On

Supplies

 

Fault: Off

 

 

Temp: Off

 

 

Ilim: Off

 

 

The correct power module voltages are present and no faults

 

 

have been detected.

 

 

 

 

Cisco XR 12410 Router Installation Guide

4-4

OL-13832-01

Page 128
Image 128
Cisco Systems XR 12410 manual Identifying Startup Issues