Chapter 2 Preparing for Installation
PRP Port Connection Guidelines
PRP Console Port Signals
The PRP console port is a DCE
Before connecting a terminal to the console port, check the terminal setting for the data transmission rate, in bits per second (bps). The terminal transmission rate setting must match the default rate of the PRP console port, which is 9600 bps. Set the terminal to these operational values: 9600 bps, 8 data bits, no parity, 2 stop bits (9600 8N2).
Table
Table | PRP Console Port Signals |
| ||
|
|
|
| |
Console Port Pin | Signal | Input/Output | Description | |
|
|
|
|
|
11 |
| — | — | — |
2 |
| DTR | Output | Data terminal ready |
|
|
|
|
|
3 |
| TxD | Output | Transmit data |
|
|
|
|
|
4 |
| GND | — | Signal ground |
|
|
|
|
|
5 |
| GND | — | Signal ground |
|
|
|
|
|
6 |
| RxD | Input | Receive data |
|
|
|
|
|
7 |
| DSR | Input | Data set ready |
|
|
|
|
|
81 |
| — | — | — |
1. These pins are not connected.
|
| Cisco XR 12410 Router Installation Guide |
|
|
|
|
| ||
|
|
|
| |
|
|
|