22 Web Management interface troubleshooting

Accessing the IP device front panel

To display the Element Manager front panel, choose one of the following options:

Select Configure > Element Manager > Front Panel.

Right-click a device on the Network Objects list or the IP or L2 Topology views and select

Element Manager > Front Panel.

The Web Management interface - Front Panel displays (Figure 282). You can use the Front Panel to manage port configuration.

FIGURE 282 Web Management Interface - Front Panel

If the device does not have a supported web interface, an error message displays: “Failed to connect to the web management interface. The product might not support web interface.”

Web Management interface troubleshooting

Table 77 lists a possible issue and the recommended solution for launching the Web Management interface.

TABLE 77

Troubleshooting

 

 

 

 

 

Problem

 

Resolution

 

 

The Web Management interface does not launch even

Workaround 1 — Editing the Java security file

when you configure both the IronWare OS products and

1

Open the java.security file located in the Install_Home\jre\lib\security\

the Management application server to use HTTPS to

 

directory in a text editor.

launch the Web Management interface. You should still

 

Install_Home is the directory where the Management application is

be able to launch the product Web Management

 

installed.

interface directly by entering the URL in a web browser.

2

Comment out the following attributes:

Failure is due to insecure SSL certificates (MD2, MD5,

#jdk.certpath.disabledAlgorithms=MD2

DES, 3DES, and RC2) deployed in the IronWare OS

#jdk.tls.disabledAlgorithms=MD5, DES, 3DES, RC2

products.

3 Save and close the file.

To configure IronWare OS products to use HTTPS, use

4 Restart the Management application service (“Stopping all services” on

the web-management https command to enable HTTPS

page 377).

in the device for web-based communication.

Workaround 2 — Removing and replacing SSL certificates

To configure the Management server to use HTTPS,

Remove the insecure certificates using the MD2, MD5, DES, 3DES, or RC2

refer to “Configuring IP communication” on page 171.

signature algorithms from the IronWare OS products and replace with more

 

 

secure ciphers such as SHA1.

 

 

742

Brocade Network Advisor IP User Manual

 

53-1003056-01

Page 794
Image 794
Brocade Communications Systems IP250 Web Management interface troubleshooting, Accessing the IP device front panel