Adding a policy monitor

36

a.Select one or more of the following checks in the Available Checks list to include them in the policy monitor:

For more information about these checks and fixes for rule violations, refer to “Switch and router policy monitors” on page 1101.

NOTE

The Check for HTTPS (secure HTTP) configuration are not supported on Network OS products and the following IronWare products: Ethernet Core routers, Ethernet Carrier Routers, Ethernet Edge router, and Data Center switch, as well as the 6650 Ethernet switch, router, and L3 router..

NOTE

The Check for Secure SSH (secure Telnet) configuration checks are not supported on the following IronWare products: Application products running 12.3.X or earlier and the 6910 Ethernet switch.

Select the Check if the product is configured to send events to this server check to determine if the Management application server is registered as an SNMP recipient and Syslog recipient.

Select the Check for HTTPS (secure HTTP) configuration check to check each target to see if HTTPS is active for device data transmission.

Select the Check for SSH (secure Telnet) configuration check to check each target to see if SSH is enabled for device data transmission.

Select the Check for SNMPv3 (secure SNMP) configuration check to check each target to see if SNMPv3 is active for device data transmission and SNMPv1 and SNMPv2 are not configured.

Select the Check for VLAN configurations match for each connection (IP only) check to determine the consistency of VLAN configurations for each connection on the selected IP devices.

b.Click the right arrow button to move the selected checks to the Selected Checks list.

c.Select the switches or routers to which you want to apply this policy in the Available Switches/Routers list and click the right arrow button.

NOTE

You can use the All Fabrics targets (under the Product Groups > System Product Groups node) in the Available Switches/Routers list) for future provisioning. Select All Fabrics and click the right arrow button to apply this policy to all discovered fabrics.

The selected switches display in the Selected Switches/Routers list.

8.To set policy monitors for hosts, select the Host Checks tab (Figure 461) and complete the following steps.