Syslogs 37

FIGURE 481 Add Syslog Filter dialog box

4.Enter a unique name for the syslog filter in the Filter Name field.

5.Enter a general description of the syslog filter in the Description field.

6.(Optional) For additional filtering, enter a text string using from 1 through 512 characters or wild card symbols in the Regular Expression field. The regular expression is used to describe a pattern in text. You can use an asterisk (*) to indicate a wildcard, as in the following examples:

*cdef: Matches a message ending with cdef

abc*: Matches a message beginning with abc

*abc*: Matches a message that contains abc

7.Select a severity level from the Severity pulldown menu. The severity level can be one of the following, and appear in descending order of severity.

Emergency

Alert

Critical

Error

Warning (Default)

Notice

Info

Debug

Events with the selected severity and those with higher severity levels are forwarded.

For example, by default, Critical severity is selected. Therefore, events with Critical, Alert, and Emergency severity levels are forwarded.

To have all traps forwarded, select Debug, the lowest severity level.

8.Select the Forward Snort® Messages check box to turn on Snort message forwarding. Refer to “Snort message forwarding” on page 1166 for more information.

9.Select the SAN, IP, or Hosts tab. Depending on the tab selected, the products available to which you can add a syslog filter display in the Available Products list.