Brocade Communications Systems IP250 Database tables and fields Physicalinterface, Physicalport

Models: IP250

1 1753
Download 1753 pages 4.1 Kb
Page 1549
Image 1549

 

Database tables and fields

I

TABLE 273 PHYSICAL_INTERFACE (Continued)

 

 

 

 

 

 

Field

Definition

Format

Size

 

 

 

 

IMAGE_VERSION

Image version of the unit in the stack. For

varchar

 

 

non-stacking device it will be always empty.

 

 

 

 

 

 

UNIT_ROLE

Indicates unit role in the stack. Possible values: 1 -

int

 

 

other, 2 - active, 3 - standby, 4 - member, 5 -

 

 

 

standalone. For non-stacking device it will be always

 

 

 

-1'

 

 

 

 

 

 

UNIT_PRIORITY

Indicates unit priority. Possible values 0 to 255. For

int

 

 

non-stacking device it will be always -1

 

 

 

 

 

 

UNIT_STATE

Used to identify unit state in the stack. Possible

int

 

 

values: 1 - local, 2 - remote, 3 - reserved, 4 - empty.

 

 

 

For non-stacking device it will be always -1

 

 

 

 

 

TABLE 274 PHYSICAL_PORT

 

 

 

 

 

 

Field

Definition

Format

Size

 

 

 

 

PHYSICAL_PORT_ID

Database unique generated identifier.

int

 

 

 

 

 

PORT_NUM

Port number from interface identifier.

smallint

 

 

 

 

 

MODULE_ID

Database ID of the module which this port is present.

int

 

 

 

 

 

IS_PORT_PRESENT

This flag is to indicate whether the port is presented

smallint

 

 

in the device. Unknown-0, Present-1 and Not present

 

 

 

-2.

 

 

 

 

 

 

TABLE_SUBTYPE

PHYSICAL_PORT table sub type.

varchar

32

 

 

 

TABLE 275 PM_COLLECTOR_MEASURE_SETTING

 

 

 

 

 

 

Field

Definition

Format

Size

 

 

 

 

COLLECTOR_ID

ID of the data_collector.

int

 

 

 

 

 

MEASURE_ID

ID of the measure.

int

 

 

 

 

TABLE 276 PM_COLLECTOR_TARGET_SETTING

 

 

 

 

 

 

Field

Definition

Format

Size

 

 

 

 

COLLECTOR_ID

ID of the data_collector.

int

 

 

 

 

 

TARGET_TYPE

Target type associated to the collector. Possible

smallint

 

 

values are 12 - IP_DEVICE_GROUP and 14 -

 

 

 

VIRTUAL_GROUP. To identify the exact target type,

 

 

 

combination of TARGET_TYPE and TARGET_ID values

 

 

 

are used.

 

 

 

 

 

 

TARGET_ID

Target Id associated to the collector. Possible values

int

 

 

are 1 - ALL_IOS_PRODUCTS, 2 -

 

 

 

ALL_NOS_PRODUCTS, 3 - ALL_IP_TRUNK, 4 -

 

 

ALL_TRILL_TRUNK, 5 - ALL_PHYSICAL_PORT, 6 - ALL_SAN_FC_PORT,

7 - ALL_SAN_TE_PORT, 8 - ALL_SAN_FCIP_TUNNEL, 9 - ALL_SAN_PRODUCT, 10 - ALL_SAN_EE_MONITOR.

Brocade Network Advisor IP User Manual

1497

53-1003056-01

 

Page 1549
Image 1549
Brocade Communications Systems IP250 Database tables and fields Physicalinterface, Physicalport, Pmcollectormeasuresetting