Brocade Communications Systems IP250 user manual Defining an event filter

Models: IP250

1 1753
Download 1753 pages 4.1 Kb
Page 412
Image 412

10 Defining an event filter

3.Click the left arrow button.

A confirmation message displays.

4.Click OK.

All devices assigned to the selected Call Home center display in the Products List. Any assigned filters are also removed.

5.Click OK to close the Call Home dialog box.

Defining an event filter

To define an event filter, complete the following steps.

1.Select Monitor > Event Notification > Call Home. The Call Home dialog box displays.

2.Click Add beneath the Call Home Event Filter list. The Call Home Event Filter dialog box displays.

3.Enter a name for the filter in the Name field.

4.Enter a name for the description in the Description field.

5.Select the check box for the events you want to include in the filter in the Available Call Home Event Types list.

To exclude the event, clear the check box. By default, all check boxes are selected during a new installation. Click Select All to select all event types in the list or select Unselect All to clear the selected event types in the list. For more information about Call Home events, refer to Appendix B, “Call Home Event Tables”.

The Available Call Home Event Types list displays the following information:

Description — The description of the event.

Type — The type of firmware for the selected event.

FRU Code/Event Type — The field-replaceable unit (FRU) code and event type for the event.

Severity — The severity of the event.

Event Reason Code — The event reason code of the event.

6.Click OK on the Call Home Event Filter dialog box.

The event filter name and the description are displayed in the Call Home dialog box.

To assign event filters to a Call Home center or a device, refer to “Assigning an event filter to a Call Home center” on page 361 or “Assigning an event filter to a device” on page 361.

7.Click OK to close the Call Home dialog box.