33 SAN real-time performance data

 

TABLE 86

Performance statistic counters

 

 

 

 

 

 

 

Counter name

 

Type

Protocol

Source OID value

Formula

 

 

 

 

 

 

RX

 

FCIP

SNMP

.1.3.6.1.2.1.31.1.1.1.6

RX = (delta value1 / (1000 * 1000)) /

 

 

 

 

 

(polling interval2)

Uncompressed

FCIP

SNMP

.1.3.6.1.4.1.1588.4.1.1.6

(delta value1 / (1000 * 1000)) /

Tx/Rx MB/sec

 

 

 

(polling interval2)

TX

 

EE Monitors

HTTP

PortRX (variable from the

TX = (delta value1 / (1000 * 1000)) /

 

 

 

 

return html file)

(polling interval2)

RX

 

EE Monitors

HTTP

PortTX (variable from the

RX = (delta value1 / (1000 * 1000)) /

 

 

 

 

return html file)

(polling interval2)

TX

 

HBA, CNA

HCM API

N/A

TX = (delta value1 / (1000 * 1000)) /

 

 

 

 

 

(polling interval2)

RX

 

HBA, CNA

HCM API

N/A

RX = (delta value1 / (1000 * 1000)) /

 

 

 

 

 

(polling interval2)

TX

 

TE

SNMP

.1.3.6.1.2.1.31.1.1.1.6

TX = (delta value1 / (1000 * 1000)) /

 

 

 

 

 

(polling interval2)

RX

 

TE

SNMP

.1.3.6.1.2.1.31.1.1.1.10

RX = (delta value1 / (1000 * 1000)) /

 

 

 

 

 

(polling interval2)

TX% / RX%

 

FC, GE,

N/A

N/A

TX% or RX% = ((TX or RX) /

 

 

HBA, CNA

 

 

((105000000 * port speed)*

 

 

 

 

 

(polling interval2))) * 100

 

 

 

 

 

If utilization is less than 1, the value is 0.0.

 

 

 

 

 

 

TX% / RX%

 

FCIP

N/A

N/A

TX% or RX% = ((bytes transferred) / (maximum bytes

 

 

 

 

 

transmitted))*100 where maximum bytes transmitted = tunnel

 

 

 

 

 

speed * 134217728 (maximum bytes transmitted 1 Gbps).

 

 

 

 

 

If utilization is less than 1, the value is 0.0.

 

 

 

 

 

 

TX% / RX%

 

TE

N/A

N/A

TX% or RX% = ((TX or RX) /

(Pre-Fabric OS

 

 

 

((105000000 * 10)*

6.4.1 release)

 

 

 

 

(polling interval2))) * 100

 

 

 

 

 

If utilization is less than 1, the value is 0.0.

 

 

 

 

 

 

Cumulative

 

FCIP

N/A

.1.3.6.1.4.1.1588.4.1.1.4

Compression Ratio = current value/ 1000

Compression

 

 

 

 

The compression ratio is the current compression ratio value.

Ratio

 

 

 

 

 

 

 

 

 

 

 

Current

 

FCIP

N/A

N/A

(ifHCInOctets + ifHCOutOctets) /

Compression

 

 

 

 

fcipExtendedLinkCompressedBytes

Ratio

 

 

 

 

 

 

 

 

 

 

 

Receive EOF

 

TE

 

.1.3.6.1.2.1.16.1.1.1.5

Receive EOF = delta value1 /

 

 

 

 

 

(1000 * 1000)

 

 

 

 

 

 

Other3

 

 

 

 

Other counters = delta value1

1.The difference of the value retrieved between two consecutive polling cycles.

2.The duration between two polling cycle in seconds.

3.Additional performance counters are detailed in Table 86.

980

Brocade Network Advisor IP User Manual

 

53-1003056-01

Page 1032
Image 1032
Brocade Communications Systems IP250 user manual Http, Hba, Cna Hcm Api, Fc, Ge, Fcip