Brocade Communications Systems IP250 user manual Importing parameter values into a configuration

Models: IP250

1 1753
Download 1753 pages 4.1 Kb
Page 837
Image 837

Importing parameter values into a configuration

25

2.Enter the user name for the product in the Product Login Account - Username field.

NOTE

If Telnet is used to log in to the device and Telnet only requires a password, then enter the password in the Password field and leave the Username field blank.

3.Enter the password for the product in the Product Login Account - Password field.

4.(IronWare only) Enter the user name assigned to management privilege levels on the device in the Product Enable Account - Username field.

NOTE

If a device only requires the enable password, then enter the password in the Password field and leave the Username field blank.

5.(IronWare only) Enter the password assigned to management privilege levels on the device in the Product Enable Account - Password field.

6.Click OK on the CLI Template dialog box

Importing parameter values into a configuration

You can define the parameter values in a comma-separated value file (CSV) and then import them into the CLI template. The CSV file can include a description of the CLI template. The description must start with a pound sign (#) and cannot be longer than 512 characters.

The first line after the description defines the header for the import. The first entry in the header must be “Target”, then list all parameters (defined on the CLI Commands tab) to be included in the import.

The target can be an IP address (IPv4 or IPv6 format), the product group name (such as San Jose products), or All (all products). The parameters can be included in any order. The application ignores empty rows or columns during import.

NOTE

All values are case sensitive (including the “Target” header).

For example, if you define the following commands on the CLI Commands tab, Table 80 shows the CSV file content required for using different values for each target and Table 81 shows the CSV file content required for using the same values for each target

!Required for LSP egress address in LSP Manager as well as a soft interface for IP routing

interface loopback $<LOOPBACK_INTERFACEINTEGER> enable

ip ospf area $<OSPF_AREAINTEGER>

ip address $<LOOPBACK_INTERFACE_IPSTRING>

Brocade Network Advisor IP User Manual

785

53-1003056-01

 

Page 837
Image 837
Brocade Communications Systems IP250 user manual Importing parameter values into a configuration