TABLE 118 IP Call Home Event
Event reason code FRU code/Event type Description Severity
N/A Ethernet Switch is not reachable. 3
N/A SW-Missing Switch is missing from the fabric. 3
199130 IP30 Power supply state changed (snTrapChasPwrSupplyFailed). 1
199131 IP31 Fan failed ( snTrap ChasFa nFail ed). 1
199136 IP36 Temperature alert (snTrapTemperatureWarning). 1
1991167 IP167 Stacking power supply failed (snTrapStackingChasPwrSupplyFailed). 1
1991169 IP169 Stacking fan failed (snTrapStackingChasFanFailed). 1
1991171 IP171 Stacking temperature warning (snTrapStackingTemperatureWarning). 1
1991177 IP177 High-speed fans needed for chassis (snTrapChasHighSpeedFansNeeded). 4
1991181 IP181 System memory out threshold (snTrapSysMemoryOutThreshold). 4
19911002 IP1002 IP CAM full (snTrapCAMOverflow). 1
19911004 IP1004 Optical monitoring alarm (snTrapOpticalMonitoringAlarm). 1
19911007 IP1007 POS monitoring alarm (snTrapPosMonitoringAlarm). 1
19911009 IP1009 Optical incompatibility error (sn TrapXfpSfpIncompatibleOptic). 1
TABLE 119 Network OS Call Home Event
Event reason code FRU code/Event type Description Severity
N/A Ethernet Switch is not reachable. 3
N/A SW-Missing Switch is missing from the fabric. 3
1426 FW-1426 Faulty or missing power supply. 3
1427 FW-1427 Faulty power supply. 3
1428 FW-1428 Missing power supply. 3
1430 FW-1430 Faulty temperature sensors. 3