Database tables and fields

I

TABLE 461 VLL_ENDPOINT_RELATION

 

 

 

 

 

 

Field

Definition

Format

Size

 

 

 

 

MPLS_SERVICE_ENDPOINT_REL

Database ID inherited from

int

 

ATION_DB_ID

MPLS_SERVICE_ENDPOINT_RELATION.

 

 

 

 

 

 

PW_ENET_PW_INSTANCE

Represents the Index of Ethernet tables

int

 

 

associated with this endpoint Instance.

 

 

 

 

 

 

COS

This value indicates the Class Of Service for this

smallint

 

 

endpoint. For VLL, this value is used to select the

 

 

 

appropriate tunnel whose COS value is either

 

 

 

same, or almost approaching this value. For

 

 

 

VLL-local, this value is applied to the ingress

 

 

 

packet of an endpoint. Allowed range is 0-7 and

 

 

 

255. 255 means COS is not explicitly configured.

 

 

 

 

 

 

TABLE 462 VMOTION_EVENT

 

 

 

 

 

 

 

Field

Definition

Format

Size

 

 

 

 

ID

Uniquely identifies the vmotion event.

int

 

 

 

 

 

SOURCE_HOST_NAME

The name of the source host at the time of the

varchar

256

 

vmotion.

 

 

 

 

 

 

SOURCE_IP_ADDRESS

IP address of the source host at the time of the

varchar

128

 

vmotion.

 

 

 

 

 

 

SOURCE_HOST_UUID

The uuid assigned by the hypervisor to the

varchar

64

 

source host.

 

 

 

 

 

 

DEST_HOST_NAME

The name of the destination host at the time of

varchar

256

 

the vmotion.

 

 

 

 

 

 

DEST_IP_ADDRESS

IP address of the destination host at the time of

varchar

128

 

the vmotion.

 

 

 

 

 

 

DEST_HOST_UUID

The uuid assigned by the hypervisor to the

varchar

64

 

destination host. This can be null in case of a

 

 

 

failed vmotion.

 

 

 

 

 

 

SOURCE_DATACENTER_NAME

Source Datacenter name.

varchar

256

 

 

 

 

DEST_DATACENTER_NAME

Destination Dataccenter name. Can be null in

varchar

256

 

case of a failed vmotion.

 

 

 

 

 

 

VM_UUID

Unique identifier for the VM to identify that VM

varchar

64

 

across vmotions.

 

 

 

 

 

 

VM_NAME

User-assigned name for the VM.

varchar

80

 

 

 

 

VM_IP_ADDRESS

The primary IPv4 or IPv6 address used by the VM

varchar

32

 

on the management LAN, if any.

 

 

 

 

 

 

VCENTER_HOST

The FQDN or the ip address of the vcenter.

varchar

256

 

 

 

 

VNIC_MACS

Comma separated vnic mac addresses.

varchar

256

 

 

 

 

START_TIME

Start time of the vmotion event.

timestamp

 

 

 

 

 

END_TIME

End time of the vmotion event, could be null

timestamp

 

 

cause of a failed vmotion.

 

 