I Database tables and fields

TABLE 343 SENSOR (Continued)

Field

Definition

Format

Size

 

 

 

 

CREATION_TIME

provides the record creation time, standard columns

timestamp

 

 

for Management application and values filled in by

 

 

 

Switch Asset Collector

 

 

 

 

 

 

LAST_UPDATE_TIME

provides the record last updated time, standard

timestamp

 

 

columns for Management application and values

 

 

 

filled in by Switch Asset Collector

 

 

 

 

 

 

FRU_TYPE

provides the type of the sensor, requested by SMIA

int

 

 

and values filled in by Switch Asset Collector will be

 

 

 

available only from FOS 6.4 switches and above. The

 

 

 

values represents FAN,PS, SLOT etc. The default

 

 

 

value is -1.

 

 

 

 

 

 

UNIT_NUMBER

provides the unit number of the sensor, requested by

int

 

 

SMIA and values filled in by Switch Asset Collector

 

 

 

will be available only from FOS 6.4 switches and

 

 

 

above . This the gives the index of the unit. For SLOT

 

 

 

FRU, this will be slot number. For FAN fru, this will be

 

 

 

fan number. The default value is -1.

 

 

 

 

 

 

STATE

provides the state of the sensor, requested by SMIA

int

 

 

and values filled in by Switch Asset Collector will be

 

 

 

available only from FOS 6.4 switches and above.

 

 

 

This gives the value whether the FRU is On or Off .

 

 

 

The default value is -1.

 

 

 

 

 

 

TABLE 344 SFLOW_CHECKPOINT

Field

Definition

Format

Size

 

 

 

 

TABLE_TO_DROP

Staging child tables previously checkpointed

varchar

40

 

(indicating that their aggregation was completed).

 

 

 

 

 

 

TABLE 345 SFLOW_HOUR_SUMMARY

Field

Definition

Format

Size

 

 

 

 

SLNUM

This column is used to store a counter value to

bigserial

 

 

identify the total row count.

 

 

 

 

 

 

TIME_IN_SECONDS

Data collection time in seconds.

int

 

 

 

 

 

DEVICE_ID

ID of the product which sends the sflow traffic.

int

 

 

 

 

 

IN_UNIT

Unit number of the incoming traffic interface. Default

smallint

 

 

value is 0.

 

 

 

 

 

 

IN_SLOT

Slot number of the incoming traffic interface.

smallint

 

 

 

 

 

IN_PORT

Port number of the incoming traffic interface.

smallint

 

 

 

 

 

OUT_UNIT

Unit number of the outgoing traffic interface. Default

smallint

 

 

value is 0.

 

 

 

 

 

 

OUT_SLOT

Slot number of the outgoing traffic interface.

smallint

 

 

 

 

 

OUT_PORT

Port number of the outgoing traffic interface.

smallint

 

 

 

 

 

IN_VLAN

Vlan ID of the incoming traffic interface.

smallint

 

 

 

 

 

OUT_VLAN

Vlan ID of the outgoing traffic interface.

smallint

 

1520

Brocade Network Advisor IP User Manual

 

53-1003056-01

Page 1572
Image 1572
Brocade Communications Systems IP250 user manual Sflowcheckpoint, Sflowhoursummary