14 System Monitor support on Network OS VDX platforms

Interface error types

Table 47 describes the interface counters that System Monitor monitors on external interfaces.

TABLE 47

Interface errors monitored by System Monitor

 

 

 

 

 

 

 

Interface error

 

Description

Port Fence

Threshold

 

 

 

support

defaults

 

 

 

 

CRC Align Errors

The total number of frames received that had a

No

Low 12

 

 

length (excluding framing bits but including Frame

 

Buffer 0

 

 

Check Sequence (FCS) octets) of from 64 through

 

High 300

 

 

1518 octets. The error indicates either a bad FCS

 

 

 

 

with an integral number of octets (an FCS error) or a

 

 

 

 

bad FCS with a non-integral number of octets (an

 

 

 

 

Alignment error).

 

 

 

 

 

 

RX Symbol Error

The interface detects an undefined (invalid) symbol

No

Low 0

 

 

received. Large symbol errors indicate a bad device,

 

Buffer 0

 

 

cable, or hardware.

 

High 5

 

 

 

 

RX IFG Violated

A minimum-length interframe gap (IFG) between

Yes

Low 5

 

 

successive frames is violated. A typical IFG is 12

 

Buffer 0

 

 

bytes.

 

High 100

 

 

 

 

RX Missing Termination

The number of frames that terminated by anything

No

Low 12

Characters

 

other than the Terminate character; this includes

 

Buffer 0

 

 

termination due to the Error character.

 

High 300

NOTE

The default settings for the above high threshold, above low threshold, below high threshold, and below low threshold actions are None.