SAN performance overview

33

Example of setting SNMP v1

HCLSwitch:admin> snmpconfig --set snmpv1

SNMP community and trap recipient configuration:

Community (rw): [test]

Trap Recipient's IP address : [172.26.1.183]

Trap recipient Severity level : (0..5) [4]

Trap recipient Port : (0..65535) [162]

Community (rw): [OrigEquipMfr]

Trap Recipient's IP address : [172.26.24.26]

Trap recipient Severity level : (0..5) [4]

Trap recipient Port : (0..65535) [162]

Community (rw): [custom]

Trap Recipient's IP address : [172.26.1.158]

Trap recipient Severity level : (0..5) [4]

Trap recipient Port : (0..65535) [162]

Community (ro): [custom]

Trap Recipient's IP address : [0.0.0.0]

Community (ro): [common]

Trap Recipient's IP address : [0.0.0.0]

Community (ro): [FibreChannel]

Trap Recipient's IP address : [172.26.1.145]

Trap recipient Severity level : (0..5) [4]

Trap recipient Port : (0..65535) [162]

-To check the SNMP v3 credentials on the device, use the snmpconfig --show snmpv3 command.

Example of SNMP v3

sw1:FID128:admin> snmpconfig --show snmpv3 SNMPv3 USM configuration:

User 1 (rw): snmpadmin1

Auth Protocol: noAuth

Priv Protocol: noPriv

User 2 (rw): snmpadmin2

Auth Protocol: noAuth

Priv Protocol: noPriv

User 3 (rw): snmpadmin3

Auth Protocol: noAuth

Priv Protocol: noPriv

User 4 (ro): snmpuser1

Auth Protocol: noAuth

Priv Protocol: noPriv

User 5 (ro): snmpuser2

Auth Protocol: noAuth

Priv Protocol: noPriv

User 6 (ro): admin

Auth Protocol: noAuth

Priv Protocol: noPriv

-To set the SNMP v3 credentials on the device, use the snmpconfig --set snmpv3 command.

FM_4100_21:admin> snmpconfig --set snmpv3

SNMPv3 user configuration(SNMP users not configured in Fabric OS user database will have physical AD and admin role as the default):

User (rw): [snmpadmin1] admin

Auth Protocol [MD5(1)/SHA(2)/noAuth(3)]: (1..3) [3] 1 New Auth Passwd:

Verify Auth Passwd:

Priv Protocol [DES(1)/noPriv(2)/3DES(3)/AES128(4)/AES2(5)/AES256(6)]): (1..6) [2] 1

New Priv Passwd: