1438 Brocade Network Advisor IP User Manual
53-1003056-01
Database tables and fields
I
SECURITY_FLAG Security Flag associated with
the circuit.
The default value is 0.
int
DSCP_CONTROL Diffserve marking for control
frame.
The default value is 0.
int
CIRCUIT_STATUS Status of the circuit.
The default value is 0.
smallint
ENABLED Is circuit enabled. Default: 0,
Values: 0|1.
The default value is 0.
smallint
MISMATCHED_CONFIGURATIONS If a tunnel is down due to
mismatched configurations
on local and remote end, this
property specifies the list of
such mismatched
configurations.
varchar 1024
CIRCUIT_STATUS_STRING Circuit Status string value
from switch for the tunnel
varchar 256
L2COS_F_CLASS The default value is 0. smallint
L2_COS_HIGH The default value is 0. smallint
L2_COS_MEDIUM The default value is 0. smallint
L2_COS_LOW The default value is 0. smallint
DSCP_F_CLASS The default value is 0. smallint
DSCP_HIGH The default value is 0. smallint
DSCP_MEDIUM The default value is 0. smallint
DSCP_LOW The default value is 0. smallint
FAILOVER_CIRCUIT Whether the circuit is
configured as failover or not.
smallint
FAILOVER_GROUP_ID Represents the failover group
id for the circuit
0 - Default Failover Group.
1 - 9 Failover Group numbers
for the circuits.
-1 - Not supported. For the
switches running less than
FOS 7.2.
int
TABLE 140 FCIP_TUNNEL_CIRCUIT (Continued)
Field Definition Format Size