Individual IP device discovery

3

8.Configure the SNMPv1 and SNMPv2c read only credentials by completing the following steps.

a.Click the SNMPv1/v2c Read Only tab.

b.Enter the community string in the Community field.

The community string can be from 1 through 16 characters long, case sensitive, and allows all printable ASCII characters. The string displays as asterisks.

NOTE

If you do not enter a community string in the field, discovery uses the "public" and "private" community strings to probe the devices.

9.Configure the Read/Write credentials by completing the following steps.

a.Click the Read/Write Credentials tab.

FIGURE 38 Read/Write credentials

b.Enter the unique user name in the Login Prompt User Name field.

The user name can be from 1 through 200 characters long, case sensitive, and allows all printable ASCII characters.

c.Enter the password in the Login Prompt Password field.

The password can be from 1 through 200 characters long, case sensitive, and allows all printable ASCII characters. The password displays as asterisks. Not applicable to DCB devices.

10.Click OK on the Add product dialog box.

The Discover Setup - IP dialog box displays with the added IP device in the Discovered Products table.

11.Click Close to close the Discover Setup - IP dialog box.

Editing IP device discovery

NOTE

Although, you can configure third-party product password settings through discovery, the Management application ignores these third-party product settings.

To edit one or more IP devices, complete the following steps.

1.Select Discover > IP Products.

The Discover Setup - IP dialog box displays.

Brocade Network Advisor IP User Manual

87

53-1003056-01

 

Page 139
Image 139
Brocade Communications Systems IP250 user manual Editing IP device discovery, Click the SNMPv1/v2c Read Only tab