H Patch troubleshooting

Problem

Resolution

 

 

Too many login and log messages received on

NOTE: This setting cannot be disabled for DCB switches.

switch console and and Master Log due to lazy

To disable lazy polling, complete the following steps.

polling.

1

Select Discover > IP Products.

 

 

The Discover Setup - IP dialog box displays.

 

2

Click the Global Settings tab.

 

3

Click the Preferences tab.

 

4

Clear the Enable lazy polling check box.

 

5

Click Apply to save your work.

 

6

Click Close to close the Discover Setup - IP dialog box.

 

7

Click Yes on the confirmation message.

 

 

 

Patch troubleshooting

 

The following section states a possible issue and the recommended solution for patch errors.

 

 

Problem

Resolution

 

 

Unable to launch the

The Windows Vista,Windows 7,or Windows 2008 R2 system enables the User Access Control (UAC) option by

SMC on a Windows

default. When the UAC option is enabled, the SMC cannot launch. If the SMC does not launch, use one of the

Vista,Windows 7,or

following options to disable the UAC option:

Windows 2008 R2

The following are the various ways we can disable UAC in vista:

system

Disable using msconfig by completing the following steps.

 

1

Select Start > Run.

 

2

Type msconfig on the Run dialog box and click OK.

 

3

Click the Tools tab on the System Configuration Utility.

 

4

Scroll down to and select the Disable UAC tool name.

 

5

Click Launch.

 

 

A command window displays and runs the disable UAC command. When the command is complete, close

 

 

the window.

 

6

Close the System Configuration Utility.

 

7

Restart the computer to apply changes.

NOTE: You can re-enable UAC using the above procedure and selecting the Enable UAC tool name in step 4.

Disable using regedit by completing the following steps.

NOTE: Before making changes to the registry, make sure you have a valid backup. In cases where you're supposed to delete or modify keys or values from the registry it is possible to first export that key or value(s) to a .REG file before performing the changes.

1Select Start > Run.

2Type regedit on the Run dialog box and click OK.

3Navigate to the following registry key:

HKEY_LOCAL_MACHINE\Software\Microsoft\Windows\CurrentVersion\Policies\System

4Right-click the EnableLUA value and select Modify.

5Change the Value data field to 0 on the Edit DWORD Value dialog box and click OK.

6Close the Registry Editor.

7Restart the computer to apply changes.

NOTE: You can re-enable UAC using the above procedure and changing the Value data field to 1 in step 5.

1364

Brocade Network Advisor IP User Manual

 

53-1003056-01

Page 1416