CGROUP - Compressor Group Select

Appendices ~ Appendix E: Serial Commands

111

CGROUP - Compressor Group Select

This command selects/reports the setting of the compressor group on each assignable processing channel.

Command form: DEVICE CGROUP <Channel> [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

CGROUP

Command form

Channel

range A–D (selects processing channel)

Value

0

= none, 1 = compressor group 1, 2 = compressor group 2,

 

3

= compressor group 3, 4 = compressor group 4,

null to return the current mode

Example: #72 CGROUP A 2 On XAP 400 unit 2 (#72), the compression group (CGROUP) for processing channel A is 2.

CHAIRO - Chairman Override Mode

This command selects/reports the setting of chairman override.

Command form: DEVICE CHAIRO <Channel> [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

CHAIRO

Command form

Channel

Range 1–4 (selects mic input)

Value

0 = Off, 1 = On, 2 = Toggle, Null to return current state

Example: #77 CHAIRO 3 1 On XAP 400 unit 7 (#77), chairman override (CHAIRO) for mic channel 3 is set on (1).