TOUT - Time Out Select

Appendices ~ Appendix E: Serial Commands

143

TOUT - Time Out Select

This command selects/reports the inactivity time out before returning to the unit title screen.

Command form: DEVICE TOUT [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

TOUT

Command

Value

0 = Off, 1–15 (select time out in minutes)

 

Null = Current mode

Example: #72 TOUT 5 On XAP 400 unit 2 (#72), the front panel of the unit will time out (TOUT) after 5 minutes.

UID - Unit ID

This command reports the unit ID. This command is read only.

Command form: DEVICE UID [Value]

Argument details

Name

Description

Units

Device

0–7 or * to select all units

 

UID

Command

 

Value

Null to return value

Hexadecimal

Example: #73 UID B465F991 The unit ID number (UID) received from XAP 400

unit 3 (#73), is B456F991.

VER - Version

This command reports the firmware version of the unit. This command is read only.

Command form: DEVICE VER [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

VER

Command

Value

Null to return value

Example: #74 VER 1.0.0 The version of the firmware (VER) programmed into

XAP 400 unit 4 (#74), is 1.0.0.