122

Appendices ~ Appendix E: Serial Commands

HOOK - Hook Flash

This command sends a hook flash. There is no query for this command. Command form: DEVICE HOOK <Channel>

Argument details

Name

Description

Device

0–7 or * to select all units

HOOK

Command form

Channel

See Groups and Channels, page 103

Example: #75 HOOK 1 On XAP 400 unit 5 (#75), send a HOOK flash to the

hybrid (1).

HOOKD - Hook Flash Duration

This command selects/reports the hook flash duration.

Command form: DEVICE HOOKD <Channel> [Value]

Argument details

Name

Description

Units

Device

0–7 or * to select all units

 

HOOK

Command form

 

Channel

See Groups and Channels, page 103

 

Value

50 to 2000

ms

 

Null to query in text

 

Example: #76 HOOKD 1 500 On XAP 400 unit 6 (#76), the hook flash duration (HOOKD) for the hybrid (1) is 500ms.

LABEL - Label

This selects/reports the label of the specific channel identified in the unit. Command form: DEVICE LABEL <Channel><Group>[In/Out] [String]

Argument details

Name

Description

Device

0–7 or * to select all units

LABEL

Command form

Channel

See Groups and Channels, page 103

Group

I, O, M, G, P, L, E, U, W, S, C (see page 103)

In/Out

0 = Output, 1 = Input (For Expansion Bus groups only)

String

String of up to 20 characters representing the label text.

 

Null to query and CLEAR to clear the label

Example: #77 LABEL 1 M WIRELESS On XAP 400 unit 7 (#77), the label (LABEL) for mic (M) channel 1 is WIRELESS.