Appendices ~ Appendix E: Serial Commands | 123 |
LFP - Lock Front Panel
This command sets and reports front panel access for the unit. When the unit is locked, access is not allowed to the unit until the unit is unlocked.
Command form: DEVICE LFP [Value]
Argument details
Name | Description | |
Device | ||
LFP | Command form | |
Value | 0 | = Unlock Panel, 1 = Lock Panel, 2 = Toggle Value, |
| 3 | = Lock when timed out |
Example: #74 LFP 1 The XAP 400 unit 4 (#74), front panel (LFP) is locked (1).
LMO - Last Mic On Mode
This command selects/reports last Mic on mode for the specified gating group.
Command form: DEVICE LMO <Channel> [Value]
Argument details
Name | Description |
Device | |
LMO | Command form |
Channel | See Groups and Channels, page 103 |
Value | 0 = Last Mic Mode disabled |
| |
| * = Last mic to stay on, Null to return the current mode |
Example: #70 LMO A 0 On XAP 400 unit 0 (#70), the Last Mic Mode (LMO) for gating group A is disabled (0).
LOCK - Preset and Macro Lock
This command selects/reports the state of the preset and macro lock. When on, the lock prevents flagged presets and macros from being altered in any way. Command form: DEVICE LOCK [Value][Password]
Argument details
Name | Description |
Device | |
LOCK | Command form |
Value | 0 = Off, 1 = On, 2 = Toggle |
Password | Only needs to be entered when changing the lock. For security, |
| this value is not returned. |
Example: #71 LOCK 1 “password” On XAP 400 unit 1 (#71), any presets or macros that have been flagged with the LOCKPRST command will be locked (LOCK) and password protected (1) with the macro/preset password (LOCKPWD).