ClearOne comm XAP 400 COMPRESS - Compressor Adjust, COMPSEL - Compression Select, Name

Models: XAP 400

1 173
Download 173 pages 53.41 Kb
Page 119
Image 119
COMPRESS - Compressor Adjust

112

Appendices ~ Appendix E: Serial Commands

COMPRESS - Compressor Adjust

This command selects/reports the setting of the compressor on processing channels. Command form DEVICE COMPRESS <Channel> [Threshold] [Ratio] [Attack] [Release] [Gain]

Argument details

Name

Description

Units

Device

0–7 or * to select all units

 

COMPRESS

Command form

 

Channel

Range A–D (selects processing channel)

 

Threshold

-30 to 20, Null to return current value

dB

Ratio

1 to 20

 

Attack

0.00 to 100.00 (select in .5ms intervals)

ms

Release

100 to 2000 (select in 5ms intervals)

ms

Gain

0.00 to 20.00

dB

Example: #71 COMPRESS A 6 5 25 250 3 On XAP 400 unit 1 (#71), the compression (COMPRESS) within processing channel A is set to have a threshold of 6dB, a ratio of 5:1 (5), an attack time of 25ms, a release time of 250ms, and a

gain of 3dB.

COMPSEL - Compression Select

This command selects/reports the compressor activation of each assignable processing channel.

Command form: DEVICE COMPSEL <Channel> [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

COMPSEL

Command form

Channel

Range A–D (selects processing channel)

Value

0 = Off, 1 = On, 2 = Toggle, Null returns current state

Example: #70 COMPSEL A 1 On XAP 400 unit 0 (#70), the compression (COMPSEL) within processing channel A is set on (1).

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760