136 | Appendices ~ Appendix E: Serial Commands |
REFSEL - PA/AEC Reference Select
This command selects/reports which output is used for each mic as a reference for power amp adaptation mode and acoustic echo cancellation where applicable. There can be only one selection per mixer.
Command form: DEVICE REFSEL <Channel> [Ref. Group] [Ref. Channel]
Argument details
Name | Description |
Device | |
REFSEL | Command |
Channel | |
Ref. Group | 0 = Output, E = Expansion bus |
Ref. Channel |
Example: #70 REFSEL 1 O 8 On XAP 400 unit 7 (#70), the PA/AEC reference REFSEL for mic channel 1 is output (O) 12.
REFSET - Reference channel setup
This command selects/reports the output the reference channel tracks. Command form: DEVICE REFSET <Channel> <Group>[Value]
Argument details
Name | Description |
Device | |
REFSET | Command |
Channel | |
Group | |
Value | 0 = none |
Example: #73 REFSET 2 4 On XAP 400 unit 3 (#73), virtual reference (2) will track gain changes mde on output channel 4.
RING - Ring Indication
This command indicates a ringing line. This command is reportable only. It cannot be queried or set.
Command form: DEVICE RING <Channel>
Argument details
Name | Description |
Device | |
RING | Command |
Channel | See Groups and Channels, page 103 |
Example: #71 RING 1 On XAP 400 unit 1 (#71), the hybrid (1) will detect an
incoming RING.