140

Appendices ~ Appendix E: Serial Commands

SIGTOUT - Signal Generator Time Out

Sets the signal generator time out for the unit.

Command form: DEVICE SIGTOUT [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

SIGGEN

Command

Value

0 = Off, 1–30 = Set time out minutes, Null = Current rate

Example: #57 SIGTOUT 15 On XAP 400 unit 7 (#77), the signal generator time out (SIGTOUT) is set to 15 minutes.

SLVL - Speech Level Control Enable/Disable

This command selects/reports the setting of speech level control for a microphone. Command form: DEVICE SLVL <Channel> [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

SLVL

Command

Channel

1–4 (select mic input)

Value

0 = Off, 1 = On, 2 = Toggle, Null = Current mode

Example:

#70 SLVL 2 M 1 On XAp 400 unit 0 (#70), the speech leveler for

mic (M) channel 2 is set to on (1).

SPEEDDIAL - Speed Dialing

This command dials a speed dial number.

Command form: DEVICE SPEEDDIAL <Channel> [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

SPEEDDIAL

Command

Channel

See Groups and Channels, page 103

Value

1 – 10, Null to query in text

Example: #71 SPEEDDIAL 15 On XAP 400 unit 1 (#71), SPEEDDIAL the hybrid (1) with the number stored in location 5.

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Page 147
Image 147
ClearOne comm XAP 400 operation manual 140, Sigtout Signal Generator Time Out, Slvl Speech Level Control Enable/Disable