CHAPTER 6: Control

There are many ways to control your XAP 400 and networked units. This chapter

explains how to set up control for the Control/Status A port using GPIO Builder, the

XAP IR Remote and ClearOne Control Panels using Remote Builder, and RS-232 port.

GPIO Builder

Control/Status A

GPIO stands for general-purpose input/output. The GPIO Builder is used to establish

the pin assignments for the 16 user definable pins on Control/Status Port A. These

pins provide control via contact closure and status via open collector functions in the

unit. Note that the pins numbered in blue are command pins; the pins numbered in

green are status pins. The default pin assignments are listed on page 96. You can

open GPIO Builder from the Flow Screen or the G-Ware toolbar.

To program control/status pins

1.Select the Control/Status A pin you want to configure.

The current (default) pin assignment is displayed in the Active (Low)/Inactive (High) Command box.

If you want to create pin assignments specific to a preset, you will need to

open the GPIO Builder from the Preset Configuration pane (see page 61) and select Use in Preset.

Figure 6.1. GPIO Builder Window

2.Select the Device Type and ID from their respective lists.

3.Select the Command from the Command list. When you select a command, a description of it appears in the Command Description box.

4.Select the argument settings from the argument lists. The options that are available depend on the command selected. When you select an argument, a description of it appears in the Argument Description box.

5.Click Apply to apply the changes you have made to the selected pin. Or, click Clear to clear any programming for the pin.

GPIO commands can be configured only for the local XAP 400 unit.

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Page 92
Image 92
ClearOne comm XAP 400 operation manual Gpio Builder, Control/Status a, To program control/status pins