System Configuration ~ Inputs and Outputs

37

Bandwidth. Bandwidth establishes the difference between the upper and lower points of a filter’s audio passband.

Bypass. The Bypass box, when selected, bypasses the selected filter.

Phase. Phase generates—on the graph—the phase relationship of the graphed frequency response.

Bypass All. Bypass All bypasses all filters.

Add Filter. Add Filter adds a filter to the graph, centered at 1kHz and 0dB.

Remove Filter. Remove Filter removes the selected node from the graph.

Table View

Figure 3.34. Filter Graph window

Table View toggles between the Graph and the Table views of the Inputs 1-4 Filter window. The Table view displays the selected filter settings in table format. You can configure filters from this view as well as in the graph view.

To configure filters

1.In either the graph or table view, select the filter type from the Type list.

Note that the configurable filter parameters displayed depend on the selected filter type.

2.Click Add Filter to add a filter to the graph or table.

3.Configure filter parameters using the previously described lists. If you are using the graph view, you can click on the node and drag it to the location you desire on the graph.

4.Click Close to exit.

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Page 44
Image 44
ClearOne comm XAP 400 operation manual Table View, To configure filters