114 | Appendices ~ Appendix E: Serial Commands  | 
DELAYSEL - Delay Select
This command selects/reports the delay activation of an assignable processing channel.
Command form: DEVICE DELAYSEL <Channel> [Value]
Argument details
Name | Description  | 
Device  | |
DELAYSEL  | Command form  | 
Channel  | |
Value  | 0 = Off, 1 = On, 2 = Toggle, Null to return current state  | 
Example: #74 DELAYSEL A 1 On XAP 400 unit 4 (#74) the delay (DELAYSEL) within processing channel A is enabled (1).
DFLTM - Default Meter
This command selects/reports the setting of the default meter. Command form: DEVICE DFLTM [Channel] [Group] [Position]
Argument details
Name | Description  | 
Device  | |
DFLTM  | Command form  | 
Channel  | |
Group  | I = Inputs, O = Outputs, M = Mic Inputs, L= Line Inputs  | 
Position  | I, A, N, G, as applicable for group  | 
  | (see Meter Type definitions, page 104)  | 
Example: #75 DFLTM 8 O A On XAP 400 unit 5 (#75), the default meter (DFLTM) is set to output (O) 8 after the gain adjustment (A).
DIAL – DTMF Dialing
This command dials a DTMF sequence or reports back the last sequence dialed. Command form: DEVICE DIAL <Channel> [Number]
Argument details
Name | Description  | 
Device  | |
DIAL  | Command form  | 
Channel  | See Group and Channels, page 103  | 
Number  | 1 – 40 Chars of   | 
  | Null to return last number dialed  | 
Example: #70 DIAL 1 1,8002835936 XAP 400 unit 0 (#70) dials (DIAL) on channel 1 the number 18002835936.