128

Appendices ~ Appendix E: Serial Commands

MINIT - Modem Initialization String

This command sets/reports the modem initialization string of the serial port when in modem mode.

Command form: DEVICE MINIT [String]

Argument details

Name

Description

Device

0–7 or * to select all units

MINIT

Command form

String

1-80 characters (select string characters to be sent to the modem

 

when the unit is initialized

 

CLEAR = clears the modem initialization string

 

Null = Current string

Example: #76 MINIT ATZ On XAP 400 unit 6 (#76), the modem initialization

string (MINIT) is ATZ.

MINMAX - Minimum and Maximum Gain Setting

This command changes or reports back the minimum and maximum gain setting for an input, output or assignable processing block.

Command form: DEVICE MINMAX <Channel> <Group> [Minimum] [Maximum]

Argument details

Name

Description

Device

0–7 or * to select all units

MINMAX

Command form

Channel

See Groups and Channels

Group

I, O, M, P, L

Minimum

-65.00 to 20.00, Null to return current settings

Maximum

-65.00 – 20.00

Example: #75 MINMAX 2 M -12 10 On XAP 400 unit 5 (#75), the minimum and maximum (MINMAX) relative gain settings for mic (M) channel 2 are -12dB

and 10dB respectively.

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Page 135
Image 135
ClearOne comm XAP 400 operation manual 128, Minit Modem Initialization String, Minmax Minimum and Maximum Gain Setting