50 | System Configuration ~ Processing |
✍ Compressors and com- pressor groups can be established only within the XAP 400 unit being configured, i.e.,
they cannot be configured from a single point across multiple units.
Figure 3.54. Compressor Setup window
Group
Use the slider to assign this compressor to a compressor group. The default is None. When you assign a compressor to a compressor
Post Compressor Gain
Adjust the compressor gain with the gain slider or by using the ▲ and ▼ buttons. The graph reflects the input/output decibel levels with the gain setting you select.
Threshold
Threshold determines the RMS level at which the compressor begins to operate. The range is from