Appendices ~ Appendix E: Serial Commands

DTONELVL - Dial Tone Level

This command selects/reports the dial tone level.

Command form: DEVICE DTONELVL <Channel> [Value]

Argument details

Name

Description

Units

Device

0–7 or * to select all units

 

DTONELVL

Command form

 

Channel

See Group and Channels, page 103

 

Value

-12.00 to 12.00

dB

 

Null to return current state

 

Example: #72 DTONELVL 1 3 On XAP 400 unit 2 (#72), the dial tone level

(DTONELVL) is set to 3dB.

FILTER - Filter Adjust

This command selects/reports the setting of filters.

Command form: DEVICE FILTER <Channel> <Group> <Node> [Type] [Frequency] [Gain] [Bandwidth]

Argument details

Name

Description

Device

0–7 or * to select all units

FILTER

Command form

Channel

See Groups and Channels, page 103

Group

See Groups and Channels, page 103

Node

1–4 (selects mic input filter)

 

1–15 (selects processing channel filter)

Name

Description

Units

Type

0

= None, 1 = All Pass, 2 = Low Pass,

 

 

3

= High Pass, 4 = Low Shelving,

 

 

5

= High Shelving, 6 = Parametric Equalizer,

 

 

7

= CD Horn, 8 = Bessel Crossover,

 

 

9

= Butterworth Crossover,

 

 

10 = Linkwitz-Riley Crossover, 11 = Notch,

 

 

Null to return the current mode

 

Frequency

0 for Null (Type 0)

Hz

 

20 to 20,000 (Type 1–6, 8–11)

Hz

 

500 to 5,000 (Type 7)

Hz

Gain

0 for Null (Type 0–3, 7, 11)

dB

 

-15.00 to 15.00 (Type 4–6)

dB per octave

 

12, 18, 24 (Type 8–9)

dB per octave

 

12, 24 (Type 10)

dB per octave

 

-80 nonadjustable (Type 11)

 

Bandwidth

0 to Null (Type 0–5, 7)

 

 

.05–5.00 (Type 6, 11)

 

 

2

= low pass, 3 = high pass (Type 8–10)

 