ClearOne comm XAP 400 FMP - First Mic Priority Mode, FPP - Front Panel Passcode, Argument details

Models: XAP 400

1 173
Download 173 pages 53.41 Kb
Page 125
Image 125
FMP - First Mic Priority Mode

118

Appendices ~ Appendix E: Serial Commands

FMP - First Mic Priority Mode

This command selects/reports first Mic priority mode for a gating group.

Command form: DEVICE FMP <Channel> [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

FMP

Command form

Channel

1–4 (selects mic inputs), A–D (selects gating group)

Value

0 = Off, 1 = On, 2 = Toggle, Null returns the current mode

Example: #75 FMP A 1 On XAP 400 unit 5 (#75), the first mic priority mode

(FMP) for gating group A is set to on (1).

FPP - Front Panel Passcode

This command sets and reports the current passcode setting for the unit. Each character in the password represents a button on the front panel. See button assignment table below. When the user is requested to unlock the front panel, they must press the buttons in the sequence of the stored password.

Command form: DEVICE FPP <char1><char2><char3><char4><char5>

Button assignment

Value Button represented

1Up arrow button

2Enter button

3ESC button

4Down arrow button

5Meter button

Argument details

Name

Description

Device

0–7 or * to select all units

FPP

Command form

Char 1–5

1–5 (see button assignments)

 

CLEAR will clear the passcode

 

Null will return current passcode

Example: #75 FPP 12345 On XAP 400 unit 5 (#75), the front panel passcode (FPP) is set to Up Arrow (1), Enter (2), Esc (3), Down Arrow (4), Meter (5).

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Page 125
Image 125
ClearOne comm XAP 400 FMP - First Mic Priority Mode, FPP - Front Panel Passcode, Button assignment, Argument details, Name