Appendices ~ Appendix E: Serial Commands

125

LVLREPORT - Level Report

This command selects level status reporting.

Command form: DEVICE LVLREPORT <Channel> <Group> [Position] [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

LVLREPORT

Command form

Channel

See Groups and Channels, page 103

Group

See Groups and Channels, page 103

Position

See Meter Type Definitions, page 104

Value

0

= Off (Delete level from list of levels to be reported)

 

1

=On (Add specified level to list of levels to be reported)

 

2

= Toggle

Example: #72 LVLREPORT 8 L I 1 On XAP 400 unit 2 (#72), the level

(LVLREPORT) of line level (L) input 8 at the input stage (I) is to be added (1) to

the report.

LVLRRATE - Level Report Rate

Sets the level report rate for the unit and activates/deactivates level repeating.

Command form: DEVICE LVLRRATE [Value]

Argument details

Name

Description

Units

Device

0–7 or * to select all units

 

LVLRRATE

Command form

 

Value

0

= Turn off reporting but leave current list

 

 

1

= Turn off reporting and clear the list

 

 

50 to 1000 = Set Rate (1 meter every x ms)

ms

 

Null to return current value

 

Example: #73 LVLRRATE 100 On XAP 400 unit 3 (#73), the level report rate

(LVLRRATE) is set to 100ms.

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Page 132
Image 132
ClearOne comm XAP 400 operation manual 125, Lvlreport Level Report, Lvlrrate Level Report Rate, = Toggle