ClearOne comm XAP 400 AGC - Automatic Gain Control, AGCSET - Automatic Gain Control Adjust, Name

Models: XAP 400

1 173
Download 173 pages 53.41 Kb
Page 116
Image 116
AGC - Automatic Gain Control

Appendices ~ Appendix E: Serial Commands

109

AGC - Automatic Gain Control

This command selects/reports the setting of automatic gain control.

Command form: DEVICE AGC <Channel> <Group> [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

AGC

Command form

Channel

See Groups and Channels on page 103

Group

1,3,7,(I,M,L)

Value

0 = Off, 1 = On, 2 = Toggle, Null to query in text

Example: #74 AGC 1 M 0 On XAP 400 unit 4 (#74), the automatic gain control (AGC) on mic (M) channel 1 is set to off (0).

AGCSET - Automatic Gain Control Adjust

This command selects/reports the settings of the AGC on the input channels.

Command form DEVICE AGCSET <Channel> <Group> [Threshold]

[Target] [Attack] [Gain]

Argument details

Name

Description

Units

Device

0–7 or * to select all units

 

AGCSET

Command form

 

Channel

See Groups and Channels on page 103

 

Group

1,3,7,(I,M,L)

 

Threshold

-50 to 0

dB

 

Null to query in text

 

Target

-30 to 20

dB

Attack

0.10–10.00 (select in .1s intervals)

s

Gain

0.00–18.00

dB

Example: #75 AGCSET 1 M -10 4 .5 18 On XAP 400 device 5 (#55) the automatic gain control (AGCSET) for mic (M) channel 1 (1) is set to have a threshold of -10dB rms, a target of 4dB rms, a response time of 500ms (.5), and a

maximum gain of 18dB.

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Page 116
Image 116
ClearOne comm XAP 400 AGC - Automatic Gain Control, AGCSET - Automatic Gain Control Adjust, Argument details, Name