Manuals
/
ClearOne comm
/
Home Audio
/
Stereo System
ClearOne comm
operation manual
XAP 400 Audio Conferencing System
Models:
XAP 400
1
2
173
173
Download
173 pages
53.41 Kb
1
2
3
4
5
6
7
8
Specifications
Install
Signal Generator
Password
Default Meter
Delay
Connecting the Control Panel
Warranty
System Configuration
Select Preset
Page 2
Image 2
XAP™ 400 Audio Conferencing System
Installation & Operation Manual
Page 1
Page 3
Page 2
Image 2
Page 1
Page 3
Contents
Audio Products XAP 400 Audio Conferencing System
XAP 400 Audio Conferencing System
XAP 400 Installation ClearOne Part No July 2002 Rev
Table of Contents
Iii
Advanced Configuration
System Configuration
Control
Operation
Appendices
Features
Introduction
Technical Support
Professional Services Group
Sales and Customer Service
ClearOne Communications EuMEA GmbH
Product registration Product returns
Unpacking
Controls and Connections
Front panel
Rear panel
Introduction ~ Controls and Connections
Networking
Expansion bus
Telephone line
Power
Operational Requirements
Introduction ~ Operational Requirements
Equipment placement
Environmental
Installation
Hardware Setup
Installation ~ Hardware Setup
To connect the unit
Expansion bus connections
Installation ~ Networking Units
Networking Units
To create an expansion bus network
Device IDs
Mixer mode
To select a mixer mode
To assign device IDs
LCD menu tree
Installation ~ LCD Programming
LCD Programming
Pressing ESC at the top of the tree does nothing
System menu
To adjust a parameter
Select Preset
RS-232 menu
Clear Password
Installation ~ LCD Programming Flow Control hardware
Enable Modem
Meter menu
Telco RX
Outputs
Processing
Telco TX
Outputs menu
Default Meter
Inputs menu
Mute
Matrix
Technical Services Group ~ 1-800-283-5936 USA ~
Windows ME
Ware Requirements
Windows
Windows NT
Creating floppy disk copies
Installing G-Ware
To install G-Ware
Creating a new site
Site Setup
Control using
To create a new site
To manually add units
Adding a XAP
To auto-detect units
File menu
Configuring Unit Properties
To configure Unit Properties
14. Unit Properties Security tab
Ware Screens
Flow Screen
Status bar
Copying and pasting settings
Safety Mute
System Configuration ~ G-Ware Screens
Matrix Screen
Process A-D routing
Audio Routing
Expansion bus O-Z routing
Cross point attenuation
System Configuration ~ Audio Routing
Matrix report
Inputs and Outputs
Inputs
PA Adapt and AEC Reference
Pwr Phantom Power
Target
To create a virtual reference
Click Close to exit the window
Meters
Filters
Non-linear Processing NLP
Active Filter
Type
33. Inputs 1-4 Filters window
To configure filters
Table View
Activation
PA Adaptive Mode
Gate
Chairman Override
Off Attenuation
Gate Ratio
Hold Time
Ambient Level
39. Virtual Reference window
To assign a gating group
To configure gating group settings
Gating Group Select
Click the Gating Group label to change the group names
Min/Max limits
Meters
AGC
48. Gain meters
Outputs
NOM
Optimizing output gain structure
To Expansion Bus O-Z
Expansion Buses
From Expansion Bus O-Z
Cmprs compressor
Processing
Processing A-D
Threshold
Group
Post Compressor Gain
Release
Ratio
Attack
Input meter
Add Filter
Phase
Bypass
Remove Filter
Delay
Changes you make in the distance and temperature fields
58. Process Gain adjust and meter
Optimizing process gain structure
Click the Telco Config button on the XAP 400 Flow Screen
Telco Setup
To configure telco settings
Have
System Configuration ~ Telco Setup
Telco Transmit
System Configuration ~ Telco Transmit and Receive
Telco Transmit and Receive
Signal-to-noise ratio without clipping the signal
Green button light illuminates when ALC is enabled
From 6dB to 15dB. Default is 6dB
Telco Receive
Overview
Presets
Creating Presets
Matrix Screen
Preset Configuration pane
Preset password is set in the Unit Properties window see
Advanced Configuration ~ Presets
To enable Acoustic Echo
Assigning virtual references to the preset
To create a preset
Storage space
To run a preset using G-Ware
Running presets
Running multiple presets simultaneously
To run a preset using front panel control
All presets are ready to run again
Room combining example
Four macros one for each configuration are set up as follows
Creating macros
To create a macro using Macro Recorder
Macros
To create a macro using Macro Editor
16 Macro Name window
To edit a macro
To add or insert a command line
Editing macros
To delete a macro
Use the macro command. See Control for more details
To run a macro using front panel control
To run a macro using the Select panel or Gpio
Running macros
To make and disconnect a call
Using the XAP
To answer a call
Audible Ring Indication
To mute
Using the Dial Interface
To dial multiple numbers
Telephone line
Operation ~ Using the Dial Interface
Touch-tone dialing
Operation~ Utilities
Signal Generator
Utilities
To use pink or white noise
Document Compare Utility
Operation ~ Utilities
To compare site files
Open window
Copying settings
Print Preview window
Copy and paste settings
Print Reports
Toolbar
To upgrade firmware
GFirm Firmware Utility
Button
15. Selecting baud rate
Message Log
Ware Switcher
To use G-Ware Switcher
Meter Views
Monitoring Views
Gate View
Operation~ Monitoring Views
To configure Meter Views
Telco meters
Telco Echo Return Loss Terl
Transmit Input
Telco Echo Return Loss Enhancement Terle
Total Telco Echo Reduction
Transmit Output
Control/Status a
To program control/status pins
Gpio Builder
Remote Builder
XAP IR Remote
Control ~ Remote Builder To program the XAP IR Remote
Select IR Remote default from the Select Remote Type list
ClearOne Control Panels
To program the Volume panel
One IR remote can be
Control ~ Remote Builder
To program the Select panel
RS-232 Port
Remote Modem Access
Serial commands
To run a command string
Command strings
To create a command string
Control ~ RS-232 Port
Technical Services Group ~ 1-800-283-5936 USA ~
Appendix a Specifications
Appendices
Appendices ~ Appendix a Specifications
Appendices ~ Appendix B Pinouts
Appendix B Pinouts
RS-232 COM DCE port pinout female
Pin Number Control
Pin Definable Type Default Description
Control/Status connectors
First 16 pins on
Control/Status a Port Pinout female
Control/Status B port pinout
Preset select bit
Preset select status for Pin
Line connector pinout
RS-485 Remote Panel a and B connectors
Set connector pinout
Pin Description
Appendices ~ Appendix C Control Panel
Connecting the Control Panel
Appendix C Control Panel
100
Appendices ~ Appendix C Control Panel
Accessory ClearOne Part Number
Appendix D Accessories
Appendices ~ Appendix D Accessories
101
102
Appendix E Serial Commands
Command structure
Conventions
Groups and channels
Appendices ~ Appendix E Serial Commands
103
Type and device IDs
104
Meter type definitions Serial command error codes
Error number Text message Explanation/Solution
105
XAP 400 Serial commands
Command Function
106
107
AA Auto-Answer Enable/ Disable
Aamb Adaptive Ambient Mode
Aconn Audible Connect / Disconnect Indication
108
AD Auto-Disconnect Enable/ Disable
AEC Acoustic Echo Canceller Enable/Disable
Aconnlvl Audible Connect/Disconnect Level
AGC Automatic Gain Control
Agcset Automatic Gain Control Adjust
109
Channel See Groups and Channels on 7,I,M,L Value
ALC Automatic Level Control
Amblvl Ambient Level Adjust
110
Baud Baud Rate
Cgroup Compressor Group Select
Chairo Chairman Override Mode
111
Compsel Compression Select
Compress Compressor Adjust
112
Gain of 3dB
113
Decay Decay Adjust
Delay Delay Adjust
Country Country Selection
114
Delaysel Delay Select
Dfltm Default Meter
Dial Dtmf Dialing
Did Device ID
Command form Channel
115
Dspver DSP Version
Dtonelvl Dial Tone Level
Filter Filter Adjust
116
Name Description Units
Flow Flow Control
117
Filtsel Filter Select
Examples
FPP Front Panel Passcode
FMP First Mic Priority Mode
118
Button assignment
Gate Gate Status
Gain Gain Adjustment
119
Channel See Groups and Channels, L, M, P, R, T Value
120
GHOLD- Gate Hold Time Adjust
Gmode Gating Mode
Gover Gating Override
Greport Gate Report
Gratio Gate Ratio Adjust
121
Grpsel Gating Group Select
Hookd Hook Flash Duration
122
Hook Hook Flash
Label Label
123
LMO Last Mic On Mode
Lock Preset and Macro Lock
LFP Lock Front Panel
124
Lockprst Apply the lock to a preset or macro
Lockpwd Set preset/macro password
LVL Level
Lvlrrate Level Report Rate
125
Lvlreport Level Report
= Toggle
126
Master Expansion Bus Master Mode
MAX Maximum Gain Setting
Macro Macro Execution/Reporting
Command form Device Mdmode Value
Mdmode Modem Mode
MIN Minimum Gain Setting
127
Minit Modem Initialization String
Minmax Minimum and Maximum Gain Setting
128
Command
Mline Mic/Line Adjust
Mpass Modem Password
129
Mtrx Matrix
Mtrxlvl Matrix Attenuation Adjustment
130
SRC = source Dest = destination Chnl = channel GRP = group
131
NCD Noise Cancellation Depth
Ncsel Noise Cancellation Select
Mute Mute
132
NLP Non-Linear Processing Adjust
NOM Number of Open Microphones Mode
Null Null the line
PP Phantom Power
Offa Off Attenuation Mode
PAA PA Adaptive Mode
Command Channel Select mic input Value
Prgstring Program String
Preset Preset Execution/Reporting
134
Supported special characters
Redial Dial the last number again
Ramp Ramp Gain Adjustment
135
Name Description Unit
Refsel PA/AEC Reference Select
Refset Reference channel setup
136
Ring Ring Indication
Ringerlvl Audible Ring Level
137
Ringer Audible Ring Selection
Rxboost Receive Boost
Rxrd Telco Receive Reduction
Rxbsten Receive Boost Enable
138
Serecho Serial Echo
Siggen Signal Generator
Sermode Serial Mode
Sftymute Safety mute
139
140
Sigtout Signal Generator Time Out
Slvl Speech Level Control Enable/Disable
Speeddial Speed Dialing
Storedial Store a Number as a Speed Dial
Tamode Telco Adapt Mode
141
String String Execution
Terl Telco Echo Return Loss
TE Telco Enable
142
Terle Telco Echo Return Loss Enhancement
UID Unit ID
143
Tout Time Out Select
VER Version
Appendix F Warranty
144
Appendices ~ Appendix F Warranty
145
FCC Part 15 Compliance
146
Appendix G Compliance
FCC Part 68 Compliance
Appendices ~ Appendix G Compliance
147
IC Compliance
EC Declaration of Conformity
Safety Information European Compliance
148
149
Telecommunications Terminal Equipment
Glossary
150
Glossary
151
152
153
Ware Software The XAP 400’s setup and configuration software
154
155
156
Required to allow remote modem access
157
Signal Delay Used for
158
159
33-35
160
Index
161
Index
162
NOM
Frequency response Phase
163
164
165
Top
Page
Image
Contents