Appendices ~ Appendix E: Serial Commands

121

GRATIO - Gate Ratio Adjust

This command selects/reports the setting of the gate ratio.

Command form: DEVICE GRATIO <Channel> [Value]

Argument details

Name

Description

Units

Device

0–7 or * to select all units

 

GRATIO

Command form

 

Channel

1–4 (select mic input)

 

Value

0 to 50

dB

 

Null to return current ratio

 

Example: #72 GRATIO 1 15 On XAP 400 unit 2 (#72), the gate ratio (GRATIO) for mic channel 1 is set to 15dB.

GREPORT - Gate Report

This command selects/reports the gate status.

Command form: DEVICE GREPORT <Value>

Argument details

Name

Description

Device

0–7 or * to select all units

GREPORT

Command form

Value

0 = Off, 1 = On, 2 = Toggle

Example: #73 GREPORT 1 On XAP 400 unit 3 (#73), the gate reporting

(GREPORT) is set to on (1).

GRPSEL - Gating Group Select

This command selects/reports which gating group each input is assigned. There can only be one selection per input.

Command form: DEVICE GRPSEL <Channel> [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

GRPSEL

Command form

Channel

1–4 (selects mic input)

Value

A–D (selects gating group), Null to return current value

Example: #74 GRPSEL 1 A On XAP 400 unit 4 (#74), mic channel 1 is assigned to gating group (GRPSEL) A.

report

Gate report sends a report on every gate change. If no mics are gated on, the will be sent every 10 seconds.

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760