Appendices ~ Appendix E: Serial Commands | 121 |
GRATIO - Gate Ratio Adjust
This command selects/reports the setting of the gate ratio.
Command form: DEVICE GRATIO <Channel> [Value]
Argument details
Name | Description | Units |
Device |
| |
GRATIO | Command form |
|
Channel |
| |
Value | 0 to 50 | dB |
| Null to return current ratio |
|
Example: #72 GRATIO 1 15 On XAP 400 unit 2 (#72), the gate ratio (GRATIO) for mic channel 1 is set to 15dB.
GREPORT - Gate Report
This command selects/reports the gate status.
Command form: DEVICE GREPORT <Value>
Argument details
Name | Description |
Device | |
GREPORT | Command form |
Value | 0 = Off, 1 = On, 2 = Toggle |
Example: #73 GREPORT 1 On XAP 400 unit 3 (#73), the gate reporting
(GREPORT) is set to on (1).
GRPSEL - Gating Group Select
This command selects/reports which gating group each input is assigned. There can only be one selection per input.
Command form: DEVICE GRPSEL <Channel> [Value]
Argument details
Name | Description |
Device | |
GRPSEL | Command form |
Channel |
|
Value |
Example: #74 GRPSEL 1 A On XAP 400 unit 4 (#74), mic channel 1 is assigned to gating group (GRPSEL) A.
✍
report
Gate report sends a report on every gate change. If no mics are gated on, the will be sent every 10 seconds.